FujiTherma · S-Mavo+ VRF outdoor module combination

We match this model to the building load, installation conditions and operating needs. Review the catalogue data below, then discuss your project with our engineering team.

Cooling
150 kW
Heating
Technical confirmation
Equipment type
Outdoor unit

SYSTEM FAMILY

S-Mavo+

Module combination: THX500WDCRRX + THX500WDCRRX + THX500WDCRRX

Check the full model code, connected equipment and installation requirements together.

See the catalogue section

THX1500WDCRRX / CATALOGUE DATA

Technical specifications.

Nominal cooling capacity
150 kW
Heating capacity (catalogue pair)
168.0 / 150.0 kW
Capacity class
54 HP
Power supply
AC three phase, 380–415 V, 50/60 Hz
Dimensions (H × W × D)
1730 × (1210 + 1210 + 1210) × 750 mm
Module net weights
296 + 296 + 296 kg
Maximum connected indoor units
64
Indoor capacity connection ratio
50–150%
Refrigerant
R410A
Module combination
THX500WDCRRX + THX500WDCRRX + THX500WDCRRX

Selection notes

The table lists two heating capacities without identifying which operating condition applies to each value. Confirm the model-specific conditions before selecting one heating rating.

Continuous heating is subject to a model-specific engineering assessment. This description does not establish simultaneous cooling and heating capability.

An engineering assessment is required for arrangements exceeding the standard 50/40 m outdoor-to-indoor height differences.

This model code denotes a combination of outdoor modules. Plan the placement, electrical supply and service access of each module separately, and assess the complete dimensions and weight.

SCA technical catalogue · Pages 51Open the technical table
SCA VRF installation at EMT Ambulance office

SCA / ON SITE

EMT Ambulans

We installed a 90 kW VRF system for 16 independent offices, with concealed ducted and cassette indoor units.

THE COMPLETE SYSTEM

Piping. Air distribution. Controls.

Equipment selection continues into the installation design. Explore the technical subjects that connect this unit to the rest of the building.

BEFORE SELECTION

Your questions, answered.

Is THX1500WDCRRX suitable for my project?

We evaluate the equipment against room loads, design temperatures, operating hours, refrigerant piping and placement conditions. Nominal capacity alone does not confirm a selection.

Does the proposal include installation?

We define the selected equipment, controls, accessories and installation scope after the site survey and technical selection. Share your plan with SCA for a project-specific proposal.

Where can I check the technical table?

The catalogue link on this page opens the relevant section of the SCA catalogue within this website.

SCA / SITE SURVEY TO COMMISSIONING

Let’s select the system for your building.

Share your floor plan, room uses and operating hours. We coordinate equipment selection, refrigerant piping, drainage, electrical supply and controls as one project.

SCA / TECHNICAL LIBRARY

FujiTherma
VRF catalogue

Open the technical tables and equipment information in the SCA catalogue. Each model page links directly to its catalogue section.