SCA MühendislikLet’s talk

SCA / MECHANICAL ENGINEERING

FujiTherma X3 Series.

Build a multi-zone system around the way the property operates. X3 combines modular outdoor equipment with load-responsive control and conditional emergency-operation options.

Istanbul based · Serving the Marmara region

FujiTherma X3 Series

X3 Series

Models in this category.

53 models

Only models in this category are listed.

53 models

Nominal capacities are listed. Model selection also depends on catalogue conditions and installation requirements.

X3 Series
ModelSeriesCoolingHeatingDetails
THX224WDCX3HXOutdoor unitX3 Series22.4 kW25 kWDetails
THX280WDCX3HXOutdoor unitX3 Series28 kW31.5 kWDetails
THX335WDCX3HXOutdoor unitX3 Series33.5 kW37.5 kWDetails
THX400WDCX3HXOutdoor unitX3 Series40 kW45 kWDetails
THX450WDCX3HXOutdoor unitX3 Series45 kW50 kWDetails
THX500WDCX3HXOutdoor unitX3 Series50.4 kW52.5 kWDetails
THX560WDCX3HXOutdoor unitX3 Series56 kW63 kWDetails
THX615WDCX3HXOutdoor unitX3 Series61.5 kW69 kWDetails
THX680WDCX3HXOutdoor unitX3 Series68 kW75 kWDetails
THX725WDCX3HXOutdoor unitX3 Series73.5 kW82.5 kWDetails
THX800WDCX3HXOutdoor unitX3 Series80 kW87.5 kWDetails
THX850WDCX3HXOutdoor unitX3 Series85.0 kW95.0 kWDetails
THX900WDCX3HXOutdoor unitX3 Series90.0 kW100.0 kWDetails
THX960WDCX3HXOutdoor unitX3 Series96.0 kW108.0 kWDetails
THX1010WDCX3HXOutdoor unitX3 Series101.0 kW113.0 kWDetails
THX1065WDCX3HXOutdoor unitX3 Series106.5 kW119.0 kWDetails
THX1130WDCX3HXOutdoor unitX3 Series113.0 kW125.0 kWDetails
THX1175WDCX3HXOutdoor unitX3 Series117.5 kW132.0 kWDetails
THX1240WDCX3HXOutdoor unitX3 Series124.0 kW138.0 kWDetails
THX1295WDCX3HXOutdoor unitX3 Series129.5 kW144.0 kWDetails
THX1360WDCX3HXOutdoor unitX3 Series136.0 kW150.0 kWDetails
THX1415WDCX3HXOutdoor unitX3 Series141.5 kW157.5 kWDetails
THX1480WDCX3HXOutdoor unitX3 Series148.0 kW162.5 kWDetails
THX1535WDCX3HXOutdoor unitX3 Series153.5 kW170.0 kWDetails
THX1600WDCX3HXOutdoor unitX3 Series160.0 kW175.0 kWDetails
THX1625WDCX3HXOutdoor unitX3 Series162.5 kW182.0 kWDetails
THX1690WDCX3HXOutdoor unitX3 Series169.0 kW188.0 kWDetails
THX1745WDCX3HXOutdoor unitX3 Series174.5 kW194.0 kWDetails
THX1810WDCX3HXOutdoor unitX3 Series181.0 kW200.0 kWDetails
THX1855WDCX3HXOutdoor unitX3 Series185.5 kW207.0 kWDetails
THX1920WDCX3HXOutdoor unitX3 Series192.0 kW213.0 kWDetails
THX1975WDCX3HXOutdoor unitX3 Series197.5 kW219.0 kWDetails
THX2040WDCX3HXOutdoor unitX3 Series204.0 kW225.0 kWDetails
THX2095WDCX3HXOutdoor unitX3 Series209.5 kW232.5 kWDetails
THX2150WDCX3HXOutdoor unitX3 Series215.0 kW240.0 kWDetails
THX2215WDCX3HXOutdoor unitX3 Series221.5 kW245.0 kWDetails
THX2280WDCX3HXOutdoor unitX3 Series228.0 kW250.0 kWDetails
THX2335WDCX3HXOutdoor unitX3 Series233.5 kW257.5 kWDetails
THX2400WDCX3HXOutdoor unitX3 Series240.0 kW262.5 kWDetails
THX2415WDCX3HXOutdoor unitX3 Series241.5 kW270.0 kWDetails
THX2480WDCX3HXOutdoor unitX3 Series248.0 kW276.0 kWDetails
THX2535WDCX3HXOutdoor unitX3 Series253.5 kW282.0 kWDetails
THX2600WDCX3HXOutdoor unitX3 Series260.0 kW288.0 kWDetails
THX2655WDCX3HXOutdoor unitX3 Series265.5 kW294.0 kWDetails
THX2720WDCX3HXOutdoor unitX3 Series272.0 kW300.0 kWDetails
THX2775WDCX3HXOutdoor unitX3 Series277.5 kW307.5 kWDetails
THX2840WDCX3HXOutdoor unitX3 Series284.0 kW312.5 kWDetails
THX2895WDCX3HXOutdoor unitX3 Series289.5 kW320.0 kWDetails
THX2960WDCX3HXOutdoor unitX3 Series296.0 kW325.0 kWDetails
THX3015WDCX3HXOutdoor unitX3 Series301.5 kW332.5 kWDetails
THX3080WDCX3HXOutdoor unitX3 Series308.0 kW337.5 kWDetails
THX3135WDCX3HXOutdoor unitX3 Series313.5 kW345.0 kWDetails
THX3200WDCX3HXOutdoor unitX3 Series320.0 kW350.0 kWDetails

Build a multi-zone system around the way the property operates. X3 combines modular outdoor equipment with load-responsive control and conditional emergency-operation options.

FujiTherma X3 Series

Technical reference

  • Single-module range: 8–28 HP — Select an approved module or combination for the project
  • Expansion-valve control: 2,000 steps — Electronic expansion valve regulates refrigerant flow as demand changes
  • VIP priority: Up to 5 indoor units — Subject to the selected system and control arrangement
  • Runtime balancing: Compatible modules and compressors — A control function; maintenance and hardware compatibility remain essential

Precise control works with correct room sizing

Temperature sensing and a 2,000-step electronic expansion valve support adjustment to changing indoor loads. We pair this control with calculated room capacity and a suitable sensor location. VIP priority can favour selected indoor units, but it does not increase total outdoor capacity. Its effect on other rooms belongs in the operating strategy.

Electrical cooling has a specific role

X3 uses refrigerant cooling for the electrical control box to support the electronics’ thermal management. This is not a claim that the compressor is cooled by that same feature. Clear outdoor airflow and service spaces remain necessary; hot discharge recirculation can still affect operation. We assess the enclosure, ambient conditions and equipment arrangement together.

Runtime rotation supports balanced operation

Runtime balancing changes the operating sequence between compatible outdoor units and compressors. It aims to share operating duty across the selected configuration. It neither removes maintenance nor guarantees a fixed service life. We set the module combination against simultaneous demand and plan maintenance around the building’s priorities.

Emergency operation depends on actual hardware

The catalogue describes outdoor-unit, compressor and fan backup scenarios. Compressor backup requires appropriate two-compressor equipment or a suitable module combination; fan backup requires a two-fan outdoor unit. The fault and remaining capacity determine what is possible. We assess critical spaces and service access without promising uninterrupted full output during every fault.

Our selection checklist

  • Confirm module combination and room-load diversity
  • Identify controllers, priority rooms and permissions
  • Evaluate fault scenarios against actual remaining capacity

Frequently asked questions

Does every X3 unit provide all backup functions?

The equipment configuration and failure conditions determine which emergency-operation procedures are available. We verify the selected modules, compressors and fans.

Does X3 offer the S-Mavo+ continuous-heating feature?

Features described for a separate product family should not be transferred to X3. We identify the technology available on the exact selected family and model.

Explore the complete system

FujiTherma VRF systemsRead the SCA FujiTherma catalogue

Plan your system with SCA

Share your floor plan, operating hours and preferred installation locations. Our Istanbul-based team supports projects across the Marmara region, from site survey and equipment selection to installation, testing and commissioning.

We coordinate the refrigerant circuit, electrical supply, drainage, ventilation and controls as one project. Your proposal identifies the selected models, accessories and installation scope.

Discuss your project Call SCA

FROM SURVEY TO INSTALLATION

Let’s put the right
system in place.

Share your plans, operating priorities and existing equipment.
We’ll define the scope together.

WhatsApp logo