SCA MühendislikLet’s talk

SCA / MECHANICAL ENGINEERING

Mitsubishi Heavy KXZ2.

Match capacity to room loads and control to the way the building operates. For offices, hotels and multi-zone premises, part-load behaviour, piping limits and winter performance matter alongside module size.

Istanbul based · Serving the Marmara region

Mitsubishi Heavy KXZ2

KXZ2 Heat Pump

Models in this category.

34 models

Only models in this category are listed.

34 models

Nominal capacities are listed. Model selection also depends on catalogue conditions and installation requirements.

KXZ2 Heat Pump
ModelSeriesCoolingHeatingDetails
FDC280KXZE2Outdoor unitKXZ2 Heat Pump28.0 kW31.5 kWDetails
FDC335KXZE2Outdoor unitKXZ2 Heat Pump33.5 kW37.5 kWDetails
FDC400KXZE2Outdoor unitKXZ2 Heat Pump40.0 kW45.0 kWDetails
FDC450KXZE2Outdoor unitKXZ2 Heat Pump45.0 kW50.0 kWDetails
FDC475KXZE2Outdoor unitKXZ2 Heat Pump47.5 kW53.0 kWDetails
FDC500KXZE2Outdoor unitKXZ2 Heat Pump50.0 kW56.0 kWDetails
FDC560KXZE2Outdoor unitKXZ2 Heat Pump56.0 kW63.0 kWDetails
FDC615KXZE2Outdoor unitKXZ2 Heat Pump61.5 kW69.0 kWDetails
FDC670KXZE2Outdoor unitKXZ2 Heat Pump67.0 kW75.0 kWDetails
FDC735KXZE2Outdoor unitKXZ2 Heat Pump73.5 kW82.5 kWDetails
FDC800KXZE2Outdoor unitKXZ2 Heat Pump80.0 kW90.0 kWDetails
FDC850KXZE2Outdoor unitKXZ2 Heat Pump85.0 kW95.0 kWDetails
FDC900KXZE2Outdoor unitKXZ2 Heat Pump90.0 kW100.0 kWDetails
FDC950KXZE2Outdoor unitKXZ2 Heat Pump95.0 kW106.0 kWDetails
FDC1000KXZE2Outdoor unitKXZ2 Heat Pump100.0 kW112.0 kWDetails
FDC1060KXZE2Outdoor unitKXZ2 Heat Pump106.0 kW119.0 kWDetails
FDC1120KXZE2Outdoor unitKXZ2 Heat Pump112.0 kW126.0 kWDetails
FDC1200KXZE2Outdoor unitKXZ2 Heat Pump120.0 kW135.0 kWDetails
FDC1250KXZE2Outdoor unitKXZ2 Heat Pump125.0 kW140.0 kWDetails
FDC1300KXZE2Outdoor unitKXZ2 Heat Pump130.0 kW145.0 kWDetails
FDC1350KXZE2Outdoor unitKXZ2 Heat Pump135.0 kW150.0 kWDetails
FDC1425KXZE2Outdoor unitKXZ2 Heat Pump142.5 kW159.0 kWDetails
FDC1450KXZE2Outdoor unitKXZ2 Heat Pump145.0 kW162.0 kWDetails
FDC1500KXZE2Outdoor unitKXZ2 Heat Pump150.0 kW168.0 kWDetails
FDC1560KXZE2Outdoor unitKXZ2 Heat Pump156.0 kW175.0 kWDetails
FDC1620KXZE2Outdoor unitKXZ2 Heat Pump162.0 kW182.0 kWDetails
FDC1680KXZE2Outdoor unitKXZ2 Heat Pump168.0 kW189.0 kWDetails
FDC560KXZXE2Outdoor unitKXZ2 Hi-COP combinations56.0 kW63.0 kWDetails
FDC850KXZXE2Outdoor unitKXZ2 Hi-COP combinations84.0 kW94.5 kWDetails
FDC900KXZXE2Outdoor unitKXZ2 Hi-COP combinations89.5 kW100.5 kWDetails
FDC950KXZXE2Outdoor unitKXZ2 Hi-COP combinations95.0 kW106.5 kWDetails
FDC1000KXZXE2Outdoor unitKXZ2 Hi-COP combinations100.5 kW112.5 kWDetails
FDC1060KXZXE2Outdoor unitKXZ2 Hi-COP combinations107.0 kW120.0 kWDetails
FDC1120KXZXE2Outdoor unitKXZ2 Hi-COP combinations113.5 kW127.5 kWDetails

Match capacity to room loads and control to the way the building operates. For offices, hotels and multi-zone premises, part-load behaviour, piping limits and winter performance matter alongside module size.

Mitsubishi Heavy KXZ2

Technical reference

  • Example model: FDC280KXZE2 — The numerical example is a 10 HP Heat Pump outdoor unit
  • Nominal capacity: 28.0 / 31.5 kW — Cooling / heating for the example model, at ISO-T1 conditions
  • Circuit: Two-pipe Heat Pump — Simultaneous heating and cooling requires the separate KXZRE2 Heat Recovery family
  • Connected indoor units: Up to 37 — FDC280KXZE2, with connection ratio and model-compatibility conditions

VTCC adapts the cycle to changing demand

VTCC adjusts target operating pressure according to indoor-unit demand. We evaluate its role when meeting rooms, corridors and work areas are not all occupied together. By identifying operating profiles, we distribute capacity around actual demand. Energy use still depends on schedules, setpoints and the selected combination; one fixed saving percentage would not describe every project.

Assess CHCC alongside winter capacity

CHCC supports low-outdoor-temperature heating behaviour and capacity management around defrost conditions. It does not eliminate defrost under every circumstance. We compare building heat loss with the outdoor design temperature and the capacity available at that point. This is particularly important for premises that stay open for extended periods.

Modular capacity needs a coordinated circuit

Outdoor-unit combinations, total indoor capacity and the piping network affect each other. The first branch, longest route and indoor-unit height differences influence selection. A generous total piping allowance does not approve every route. We coordinate the circuit, electrical supply and outdoor discharge path in the same design.

Give room control and central control clear roles

Room controllers manage local comfort; central controllers manage schedules and site-wide permissions. BMS integration and consumption allocation require compatible controllers, interfaces and system design. We clarify who can change setpoints, which areas run after hours and which operating information the building manager needs.

Our selection checklist

  • Choose Heat Pump or Heat Recovery around actual mode requirements
  • Check available capacity at the winter design temperature
  • Assess module combinations and simultaneous loads
  • Define piping, controller and building-management scope

Frequently asked questions

Can each room select its own heating or cooling mode?

A two-pipe KXZ2 Heat Pump circuit operates in one common mode at a time. Where opposite modes are required simultaneously, we design the appropriate KXZRE2 Heat Recovery system.

Can 37 indoor units all deliver full rating at once?

The connection limit is not a simultaneous-capacity guarantee. We verify total load, connection ratio, outdoor conditions and installation corrections.

Explore the complete system

Mitsubishi Heavy Industries VRF systemsRead the SCA Mitsubishi Heavy catalogue

Plan your system with SCA

Share your floor plan, operating hours and preferred installation locations. Our Istanbul-based team supports projects across the Marmara region, from site survey and equipment selection to installation, testing and commissioning.

We coordinate the refrigerant circuit, electrical supply, drainage, ventilation and controls as one project. Your proposal identifies the selected models, accessories and installation scope.

Discuss your project Call SCA

FROM SURVEY TO INSTALLATION

Let’s put the right
system in place.

Share your plans, operating priorities and existing equipment.
We’ll define the scope together.

WhatsApp logo