High-static ducted / INDOOR UNIT
DHTHX112HHX.
FujiTherma · High-static ducted VRF indoor unit
We match this model to the building load, installation conditions and operating needs. Review the catalogue data below, then discuss your project with our engineering team.
- Cooling
- 11.2 kW
- Heating
- 12.5 kW
- Equipment type
- Indoor unit

DHTHX112HHX / CATALOGUE DATA
Technical specifications.
- DC high static — Power supply
- AC single phase, 220–240 V, 50/60 Hz
- DC high static — Power input — cooling
- 132 W
- DC high static — Power input — heating
- 132 W
- DC high static — Dimensions (H × W × D)
- 300 × 1100+75 × 800 mm
- DC high static — Net weight
- 40 kg
- DC high static — Packaging dimensions (H × W × D)
- 415 × 1345 × 950 mm
- DC high static — Gross weight
- 48 kg
- DC high static — Airflow — highest listed standard speed
- 28 m³/min
- DC high static — Sound pressure — highest listed speed
- 37 dB(A)
- DC high static — External static pressure
- 50 Pa (settings: 50/60/70/80/90/100/110/120/130/140/150/160/170/180/190/200 Pa)
- DC high static — Liquid line connection
- 3/8 in
- DC high static — Gas line connection
- 5/8 in
- DC high static — Condensate drain
- I.D. 32 mm
- High static — Power supply
- AC single phase, 220–240 V, 50 Hz
- High static — Power input — cooling
- 0.25 (0.34, *1) kW
- High static — Power input — heating
- 0.25 (0.34, *1) kW
- High static — Dimensions (H × W × D)
- 300 × 1100+75 × 800 mm
- High static — Net weight
- 45 (44, *1) kg
- High static — Packaging dimensions (H × W × D)
- 415 × 1345 × 950 mm
- High static — Gross weight
- 52 (52, *1) kg
- High static — Airflow — highest listed standard speed
- 28 m³/min
- High static — External static pressure
- 220–240 V/50 Hz, 208 V/60 Hz: 120 (90) Pa; 230 V/60 Hz: 170 (150) Pa
- High static — Liquid line connection
- 3/8 in
- High static — Gas line connection
- 5/8 in
- High static — Condensate drain
- I.D. 32 mm
- Nominal cooling capacity
- 11.2 kW
- Nominal heating capacity
- 12.5 kW
Selection notes
This code appears in both the DC high-static and high-static ducted tables. Cabinet, fan power, weight and static pressure can differ; do not merge the two tables into one device version.

SCA / ON SITE
EMT Ambulans
We installed a 90 kW VRF system for 16 independent offices, with concealed ducted and cassette indoor units.
THE COMPLETE SYSTEM
Piping. Air distribution. Controls.
Equipment selection continues into the installation design. Explore the technical subjects that connect this unit to the rest of the building.
BEFORE SELECTION
Your questions, answered.
Is DHTHX112HHX suitable for my project?
We evaluate the equipment against room loads, design temperatures, operating hours, refrigerant piping and placement conditions. Nominal capacity alone does not confirm a selection.
Does the proposal include installation?
We define the selected equipment, controls, accessories and installation scope after the site survey and technical selection. Share your plan with SCA for a project-specific proposal.
Where can I check the technical table?
The catalogue link on this page opens the relevant section of the SCA catalogue within this website.
SCA / SITE SURVEY TO COMMISSIONING
Let’s select the system for your building.
Share your floor plan, room uses and operating hours. We coordinate equipment selection, refrigerant piping, drainage, electrical supply and controls as one project.
SCA / TECHNICAL LIBRARY
FujiTherma
VRF catalogue
Open the technical tables and equipment information in the SCA catalogue. Each model page links directly to its catalogue section.