X3 Series / OUTDOOR UNIT

THX2480WDCX3HX.

FujiTherma · X3 Series VRF outdoor module combination

We match this model to the building load, installation conditions and operating needs. Review the catalogue data below, then discuss your project with our engineering team.

Cooling
248.0 kW
Heating
276.0 kW
Equipment type
Outdoor unit

SYSTEM FAMILY

X3 Series

Module combination: THX680WDCX3HX + THX680WDCX3HX + THX560WDCX3HX + THX560WDCX3HX

Check the full model code, connected equipment and installation requirements together.

See the catalogue section

THX2480WDCX3HX / CATALOGUE DATA

Technical specifications.

Nominal cooling capacity
248.0 kW
Nominal heating capacity
276.0 kW
Capacity class
88 HP
Power supply
AC three phase, 380–415 V / 50 Hz; 380 V / 60 Hz
Dimensions (H × W × D)
1730 × (1350 + 1350 + 1350 + 1350) × 750 mm
Net weight
1362.0 kg
Maximum connected indoor units
64
Indoor capacity connection ratio
50–150%
Refrigerant
R410A
Module combination
THX680WDCX3HX + THX680WDCX3HX + THX560WDCX3HX + THX560WDCX3HX

Selection notes

Nominal capacities apply at the catalogue test conditions. We check project capacity against design temperatures, refrigerant piping and the connected indoor units.

The starred 90 m height difference is conditional. Projects exceeding the standard 50/40 m outdoor-to-indoor height limits require an engineering review.

This model code denotes a combination of outdoor modules. Plan the placement, electrical supply and service access of each module separately, and assess the complete dimensions and weight.

SCA technical catalogue · Pages 41Open the technical table
SCA VRF installation at EMT Ambulance office

SCA / ON SITE

EMT Ambulans

We installed a 90 kW VRF system for 16 independent offices, with concealed ducted and cassette indoor units.

THE COMPLETE SYSTEM

Piping. Air distribution. Controls.

Equipment selection continues into the installation design. Explore the technical subjects that connect this unit to the rest of the building.

BEFORE SELECTION

Your questions, answered.

Is THX2480WDCX3HX suitable for my project?

We evaluate the equipment against room loads, design temperatures, operating hours, refrigerant piping and placement conditions. Nominal capacity alone does not confirm a selection.

Does the proposal include installation?

We define the selected equipment, controls, accessories and installation scope after the site survey and technical selection. Share your plan with SCA for a project-specific proposal.

Where can I check the technical table?

The catalogue link on this page opens the relevant section of the SCA catalogue within this website.

SCA / SITE SURVEY TO COMMISSIONING

Let’s select the system for your building.

Share your floor plan, room uses and operating hours. We coordinate equipment selection, refrigerant piping, drainage, electrical supply and controls as one project.

SCA / TECHNICAL LIBRARY

FujiTherma
VRF catalogue

Open the technical tables and equipment information in the SCA catalogue. Each model page links directly to its catalogue section.