KXZ water cooled / OUTDOOR UNIT
FDC450KXZWE1.
Mitsubishi Heavy · KXZ water cooled VRF outdoor module combination
We match this model to the building load, installation conditions and operating needs. Review the catalogue data below, then discuss your project with our engineering team.
- Cooling
- 45.0 kW
- Heating
- 50.0 kW
- Equipment type
- Outdoor unit
SYSTEM FAMILY
KXZ water cooled
2 outdoor modules
Check the full model code, connected equipment and installation requirements together.
See the catalogue sectionFDC450KXZWE1 / CATALOGUE DATA
Technical specifications.
- Nominal cooling capacity
- 45.0 kW
- Nominal heating capacity
- 50.0 kW
- Power supply
- three phase, 380–415 V, 50 Hz
- Capacity class
- 16 HP
- Number of modules
- 2
- Single-module dimensions (H × W × D)
- 1100 × 780 × 550 mm
- Refrigerant
- R410A
Selection notes
These water-cooled capacities apply at the catalogue water inlet temperature and flow rate. Do not compare them directly with air-cooled ratings taken at different test conditions.
This model code denotes a combination of outdoor modules. Plan the placement, electrical supply and service access of each module separately, and assess the complete dimensions and weight.

SCA / ON SITE
EMT Ambulans
We installed a 90 kW VRF system for 16 independent offices, with concealed ducted and cassette indoor units.
THE COMPLETE SYSTEM
Piping. Air distribution. Controls.
Equipment selection continues into the installation design. Explore the technical subjects that connect this unit to the rest of the building.
BEFORE SELECTION
Your questions, answered.
Is FDC450KXZWE1 suitable for my project?
We assess connected loads, water inlet temperature, water flow, piping and module placement together. A water-cooled nominal rating requires checking against the actual water-circuit conditions before selection.
Does the proposal include installation?
We define the selected equipment, controls, accessories and installation scope after the site survey and technical selection. Share your plan with SCA for a project-specific proposal.
Where can I check the technical table?
The catalogue link on this page opens the relevant section of the SCA catalogue within this website.
SCA / SITE SURVEY TO COMMISSIONING