Maximum cooling
28 kW
Maximum heating
28 kW
Equipment type
Hydro module
Mitsubishi Heavy HMU hydro module unit
Mitsubishi Heavy · HMU hydro module

HMU280KXZE1 / CATALOGUE DATA

Technical specifications.

Maximum cooling capacity
28 kW
Maximum heating capacity
28 kW
Power supply
single phase, 220–240 V, 50 Hz
Body dimensions (H × W × D)
860 × 550 × 400 mm
Water flow range
24–80 l/min
IP rating
IP20

Selection notes

HMU cooling and heating capacities are maximum hydro module ratings, not nominal air-conditioning capacities. Select the module with the required water temperatures and flow rate.

Allow the additional height required by the pipe outlet beyond the body height. Check the installation and service space against the complete dimensions.

Water inlet and outlet temperature limits depend on outdoor temperature and mixed operation with air-to-air indoor units. Confirm the operating envelope for the selected system arrangement.

SCA technical catalogue · Pages 115Open the technical table
SCA VRF installation at EMT Ambulance office

SCA / ON SITE

EMT Ambulans

We installed a 90 kW VRF system for 16 independent offices, with concealed ducted and cassette indoor units.

THE COMPLETE SYSTEM

Water circuit. Piping. Controls.

Equipment selection continues into the installation design. Explore the technical subjects that connect this unit to the rest of the building.

BEFORE SELECTION

Your questions, answered.

Is HMU280KXZE1 suitable for my project?

We assess required water temperatures, flow, the hydraulic circuit and building load alongside the outdoor-unit conditions. Maximum hydro module capacity alone does not confirm a selection.

Does the proposal include installation?

We define the selected equipment, controls, accessories and installation scope after the site survey and technical selection. Share your plan with SCA for a project-specific proposal.

Where can I check the technical table?

The catalogue link on this page opens the relevant section of the SCA catalogue within this website.

SCA / SITE SURVEY TO COMMISSIONING

Let’s select the system for your building.

Share your floor plan, room uses and operating hours. We coordinate equipment selection, refrigerant piping, drainage, electrical supply and controls as one project.

SCA / TECHNICAL LIBRARY

Mitsubishi Heavy
VRF catalogue

Open the technical tables and equipment information in the SCA catalogue. Each model page links directly to its catalogue section.