Conceal the equipment while keeping airflow measurable. We select the static-pressure class against the resistance of the complete duct and terminal system.

Istanbul based · Serving the Marmara region

FujiTherma Concealed Ducted Indoor Units

Ducted

Models in this category.

27 models

Only models in this category are listed.

27 models

Nominal capacities are listed. Model selection also depends on catalogue conditions and installation requirements.

Ducted
ModelSeriesCoolingHeatingDetails
DHTHX22HHXIndoor unitHigh-static ducted2.2 kW2.5 kWDetails
DHTHX28HHXIndoor unitHigh-static ducted2.8 kW3.2 kWDetails
DHTHX36HHXIndoor unitHigh-static ducted3.6 kW4 kWDetails
DHTHX45HHXIndoor unitHigh-static ducted4.5 kWTechnical confirmationDetails
DHTHX56HHXIndoor unitHigh-static ducted5.6 kW6.3 kWDetails
DHTHX63HHXIndoor unitHigh-static ductedTechnical confirmationTechnical confirmationDetails
DHTHX71HHXIndoor unitHigh-static ducted7.1 kW8 kWDetails
DHTHX90HHXIndoor unitHigh-static ducted9 kW10 kWDetails
DHTHX112HHXIndoor unitHigh-static ducted11.2 kW12.5 kWDetails
DHTHX125HHXIndoor unitDC high-static ducted12.5 kW14 kWDetails
DHTHX142HHXIndoor unitHigh-static ducted14 kW16 kWDetails
DHTHX160HHXIndoor unitHigh-static ducted16 kW18 kWDetails
DHTHX84HHXIndoor unitHigh-static ducted8 kW9 kWDetails
DHTHX224HHXIndoor unitHigh-static ducted22.4 kW25 kWDetails
DHTHX280HHXIndoor unitHigh-static ducted28 kW31.5 kWDetails
DTHX22HHXIndoor unitLow-static ducted2.2 kW2.5 kWDetails
DTHX28HHXIndoor unitLow-static ducted2.8 kW3.2 kWDetails
DTHX36HHXIndoor unitLow-static ducted3.6 kW4 kWDetails
DTHX45HHXIndoor unitLow-static ducted4.5 kW5 kWDetails
DTHX56HHXIndoor unitLow-static ducted5.6 kW6.3 kWDetails
DTHX63HHXIndoor unitLow-static ducted6.3 kW7.1 kWDetails
DTHX71HHXIndoor unitLow-static ducted7.1 kW8 kWDetails
DTHX84HHXIndoor unitLow-static ducted8 kW9 kWDetails
DTHX90HHXIndoor unitLow-static ducted9 kW10 kWDetails
DTHX112HHXIndoor unitLow-static ducted11.2 kW12.5 kWDetails
DTHX142HHXIndoor unitLow-static ducted14 kW16 kWDetails
DTHX160HHXIndoor unitLow-static ducted16 kW18 kWDetails

Conceal the equipment while keeping airflow measurable. We select the static-pressure class against the resistance of the complete duct and terminal system.

FujiTherma Concealed Ducted Indoor Units

Technical reference

  • Reference family: Low-static DTHX…HHX — Numerical examples below refer to this separate family
  • Nominal cooling range: 2.2–16 kW — Exact capacity depends on the DTHX model
  • Static-pressure reference: 30 / 60 Pa — Model-dependent; check required airflow and the selected duty
  • Body height: 270 / 300 mm — Model-dependent; service and drain clearances are additional

Select the fan at the real air-system duty

Supply ducts, return grilles, bends, filters and diffusers create resistance. We calculate it at the required airflow, then choose the matching unit and fan setting. A higher pressure rating is not automatically quieter or more efficient. The unit must deliver the room’s design airflow through the actual installation.

Keep low- and high-static families distinct

The listed capacity, pressure and height examples describe the low-static DTHX…HHX range. Automatic external-static-pressure adjustment applies to compatible high-static models and is not transferred to the low-static reference simply because both are concealed units. Family and full model code remain visible in the selection file.

Resolve data conflicts before procurement

Some DHTHX45HHX and DHTHX63HHX source entries contain conflicting model values. We do not repeat those figures as confirmed capacity. Electrical power and supply for DHTHX224/280 also need model-specific confirmation. Where a table is ambiguous, we obtain the relevant current data before approving equipment or electrical works.

Concealment must preserve maintenance access

Return-air area, filter removal, fan access and drain-tray inspection need a clear route. We check insulation continuity and condensate gradients before closing the ceiling. At commissioning, measured supply quantities and branch balance are compared with the design, so a good-looking grille is supported by effective air distribution.

Our selection checklist

  • Check the exact static-pressure family and model
  • Calculate pressure loss and verify design airflow
  • Agree filter, fan and drainage access before ceiling closure

Frequently asked questions

Does automatic static-pressure control correct undersized ducts?

It can support adjustment on compatible models, but it does not repair a poorly sized duct or unsuitable terminal. The design duty must be checked first.

Why are some model values omitted?

Conflicting source entries need clarification before they can support selection. We use verified subgroup values and confirm the exact model before procurement.

Explore the complete system

FujiTherma VRF systemsRead the SCA FujiTherma catalogue

Plan your system with SCA

Share your floor plan, operating hours and preferred installation locations. Our Istanbul-based team supports projects across the Marmara region, from site survey and equipment selection to installation, testing and commissioning.

We coordinate the refrigerant circuit, electrical supply, drainage, ventilation and controls as one project. Your proposal identifies the selected models, accessories and installation scope.