SCA MühendislikLet’s talk

SCA / MECHANICAL ENGINEERING

FujiTherma Cassette Indoor Units.

Distribute air around the room without making the panel the only selection criterion. We coordinate capacity, ceiling space, vane direction and optional comfort controls.

Istanbul based · Serving the Marmara region

FujiTherma Cassette Indoor Units

Cassette

Models in this category.

35 models

Only models in this category are listed.

35 models

Nominal capacities are listed. Model selection also depends on catalogue conditions and installation requirements.

Cassette
ModelSeriesCoolingHeatingDetails
CTHX28HHXIndoor unitFour-way cassette2.8 kW3.2 kWDetails
CTHX36HHXIndoor unitFour-way cassette3.6 kW4 kWDetails
CTHX45HHXIndoor unitFour-way cassette4.5 kW5 kWDetails
CTHX56HHXIndoor unitFour-way cassette5.6 kW6.3 kWDetails
CTHX63HHXIndoor unitFour-way cassette6.3 kW7.1 kWDetails
CTHX71HHXIndoor unitFour-way cassette7.1 kW8 kWDetails
CTHX80HHXIndoor unitFour-way cassette8 kW9 kWDetails
CTHX90HHXIndoor unitFour-way cassette9 kW10 kWDetails
CTHX112HHXIndoor unitFour-way cassette11.2 kW12.5 kWDetails
CTHX142HHXIndoor unitFour-way cassette14 kW16 kWDetails
CTHX160HHXIndoor unitFour-way cassette16 kW18 kWDetails
CSTHX15HHXIndoor unitMini Four-way cassette1.5 kW2 kWDetails
CSTHX22HHXIndoor unitMini Four-way cassette2.2 kW2.5 kWDetails
CSTHX28HHXIndoor unitMini Four-way cassette2.8 kW3.3 kWDetails
CSTHX36HHXIndoor unitMini Four-way cassette3.6 kW4.2 kWDetails
CSTHX45HHXIndoor unitMini Four-way cassette4.5 kW5 kWDetails
CSTHX50HHXIndoor unitMini Four-way cassette5 kW5.6 kWDetails
CSTHX56HHXIndoor unitMini Four-way cassette5.6 kW6.3 kWDetails
CATHX22HHXIndoor unitOne-way cassette2.2 kW2.5 kWDetails
CATHX28HHXIndoor unitOne-way cassette2.8 kW3.2 kWDetails
CATHX36HHXIndoor unitOne-way cassette3.6 kW4 kWDetails
CATHX43HHXIndoor unitOne-way cassette4.5 kW5 kWDetails
CATHX56HHXIndoor unitOne-way cassette5.6 kW6.3 kWDetails
CATHX71HHXIndoor unitOne-way cassette7.1 kW8 kWDetails
C2THX22HHXIndoor unitTwo-way cassette2.2 kW2.8 kWDetails
C2THX28HHXIndoor unitTwo-way cassette2.8 kW3.3 kWDetails
C2THX36HHXIndoor unitTwo-way cassette3.6 kW4 kWDetails
C2THX43HHXIndoor unitTwo-way cassette4.3 kW4.9 kWDetails
C2THX56HHXIndoor unitTwo-way cassette5.6 kW6.5 kWDetails
C2THX71HHXIndoor unitTwo-way cassette7.1 kW8 kWDetails
C2THX84HHXIndoor unitTwo-way cassette8.4 kW9 kWDetails
C2THX90HHXIndoor unitTwo-way cassette9 kW10 kWDetails
C2THX112HHXIndoor unitTwo-way cassette11.2 kW13 kWDetails
C2THX140HHXIndoor unitTwo-way cassette14 kW16 kWDetails
C2THX160HHXIndoor unitTwo-way cassette16 kW18 kWDetails

Distribute air around the room without making the panel the only selection criterion. We coordinate capacity, ceiling space, vane direction and optional comfort controls.

FujiTherma Cassette Indoor Units

Technical reference

  • Standard cassette range: 2.8–16 kW — CTHX…HHX family; model-specific capacity
  • Mini cassette range: 1.5–5.6 kW — CSTHX…HHX family
  • Standard body height: 238 / 288 mm — Varies with selected capacity; panel and installation space are additional
  • Mini geometry: 215 mm body height — 570 × 570 mm body; separate 620 × 620 mm panel

Body dimensions and panel dimensions are different

A cassette’s visible panel may fit the ceiling grid while the body and connections still need more space above. We coordinate suspension, insulated pipes, condensate drainage and service access with lighting and sprinkler positions. Model-specific body and panel dimensions must be checked together before the ceiling layout is approved.

Vane direction should follow occupancy

Compatible four-way cassettes can provide independently adjusted vanes. We direct the air around desks, waiting seats and the room’s perimeter demand. Compatible breeze panels use micro-perforated airflow arrangements for softer distribution. Panel and controller compatibility must be confirmed rather than assume every cassette includes the same functions.

Sensors require the right equipment and placement

Motion-sensor options can support airflow behaviour and operating management around occupancy. Their usefulness depends on the selected unit, panel, sensor and controller. We identify those items in the proposal and check the expected seating and walking routes so the control strategy reflects the occupied room.

Soft airflow is not outdoor-air ventilation

A breeze feature changes room-air distribution; it does not supply the required outdoor-air quantity. We assess ventilation separately and account for its thermal and humidity loads. At commissioning, drainage, fan duty and occupied-zone airflow are checked alongside temperature control.

Our selection checklist

  • Confirm the body, panel and clear ceiling depth
  • Select compatible vane, sensor and control functions
  • Coordinate room airflow, drainage and separate ventilation

Frequently asked questions

Are breeze and motion sensors standard on all models?

These features depend on the compatible indoor unit, panel, sensors and controller selected. We specify the complete combination.

Is the 620 mm dimension the mini cassette body size?

The mini body is 570 × 570 mm; the panel is separately 620 × 620 mm. Installation access and connection clearances are additional.

Explore the complete system

FujiTherma VRF systemsRead the SCA FujiTherma catalogue

Plan your system with SCA

Share your floor plan, operating hours and preferred installation locations. Our Istanbul-based team supports projects across the Marmara region, from site survey and equipment selection to installation, testing and commissioning.

We coordinate the refrigerant circuit, electrical supply, drainage, ventilation and controls as one project. Your proposal identifies the selected models, accessories and installation scope.

Discuss your project Call SCA

FROM SURVEY TO INSTALLATION

Let’s put the right
system in place.

Share your plans, operating priorities and existing equipment.
We’ll define the scope together.

WhatsApp logo