KXZ water cooled / OUTDOOR UNIT

FDC1000KXZWE1.

Mitsubishi Heavy · KXZ water cooled VRF outdoor module combination

We match this model to the building load, installation conditions and operating needs. Review the catalogue data below, then discuss your project with our engineering team.

Cooling
100.0 kW
Heating
112.0 kW
Equipment type
Outdoor unit

SYSTEM FAMILY

KXZ water cooled

3 outdoor modules

Check the full model code, connected equipment and installation requirements together.

See the catalogue section

FDC1000KXZWE1 / CATALOGUE DATA

Technical specifications.

Nominal cooling capacity
100.0 kW
Nominal heating capacity
112.0 kW
Power supply
three phase, 380–415 V, 50 Hz
Capacity class
36 HP
Number of modules
3
Single-module dimensions (H × W × D)
1100 × 780 × 550 mm
Refrigerant
R410A

Selection notes

These water-cooled capacities apply at the catalogue water inlet temperature and flow rate. Do not compare them directly with air-cooled ratings taken at different test conditions.

This model code denotes a combination of outdoor modules. Plan the placement, electrical supply and service access of each module separately, and assess the complete dimensions and weight.

SCA technical catalogue · Pages 81Open the technical table
SCA VRF installation at EMT Ambulance office

SCA / ON SITE

EMT Ambulans

We installed a 90 kW VRF system for 16 independent offices, with concealed ducted and cassette indoor units.

THE COMPLETE SYSTEM

Piping. Air distribution. Controls.

Equipment selection continues into the installation design. Explore the technical subjects that connect this unit to the rest of the building.

BEFORE SELECTION

Your questions, answered.

Is FDC1000KXZWE1 suitable for my project?

We assess connected loads, water inlet temperature, water flow, piping and module placement together. A water-cooled nominal rating requires checking against the actual water-circuit conditions before selection.

Does the proposal include installation?

We define the selected equipment, controls, accessories and installation scope after the site survey and technical selection. Share your plan with SCA for a project-specific proposal.

Where can I check the technical table?

The catalogue link on this page opens the relevant section of the SCA catalogue within this website.

SCA / SITE SURVEY TO COMMISSIONING

Let’s select the system for your building.

Share your floor plan, room uses and operating hours. We coordinate equipment selection, refrigerant piping, drainage, electrical supply and controls as one project.

SCA / TECHNICAL LIBRARY

Mitsubishi Heavy
VRF catalogue

Open the technical tables and equipment information in the SCA catalogue. Each model page links directly to its catalogue section.