KXZ2 Hi-COP combinations / OUTDOOR UNIT

FDC900KXZXE2.

Mitsubishi Heavy · KXZ2 Hi-COP VRF outdoor module combination

We match this model to the building load, installation conditions and operating needs. Review the catalogue data below, then discuss your project with our engineering team.

Cooling
89.5 kW
Heating
100.5 kW
Equipment type
Outdoor unit

SYSTEM FAMILY

KXZ2 Hi-COP combinations

Check the full model code, connected equipment and installation requirements together.

See the catalogue section

FDC900KXZXE2 / CATALOGUE DATA

Technical specifications.

Nominal cooling capacity
89.5 kW
Nominal heating capacity
100.5 kW
Power supply
three phase, 380–415 V, 50 Hz
Body dimensions (H × W × D)
1697 × 4050 × 720 mm
Capacity class
32 HP
Refrigerant
R410A

Selection notes

Nominal capacities apply at the catalogue test conditions. We check project capacity against design temperatures, refrigerant piping and the connected indoor units.

This is an outdoor module combination selected for efficiency. Use its technical-table capacity rather than calculating capacity from the model code.

SCA technical catalogue · Pages 44Open the technical table
SCA VRF installation at EMT Ambulance office

SCA / ON SITE

EMT Ambulans

We installed a 90 kW VRF system for 16 independent offices, with concealed ducted and cassette indoor units.

THE COMPLETE SYSTEM

Piping. Air distribution. Controls.

Equipment selection continues into the installation design. Explore the technical subjects that connect this unit to the rest of the building.

BEFORE SELECTION

Your questions, answered.

Is FDC900KXZXE2 suitable for my project?

We evaluate the equipment against room loads, design temperatures, operating hours, refrigerant piping and placement conditions. Nominal capacity alone does not confirm a selection.

Does the proposal include installation?

We define the selected equipment, controls, accessories and installation scope after the site survey and technical selection. Share your plan with SCA for a project-specific proposal.

Where can I check the technical table?

The catalogue link on this page opens the relevant section of the SCA catalogue within this website.

SCA / SITE SURVEY TO COMMISSIONING

Let’s select the system for your building.

Share your floor plan, room uses and operating hours. We coordinate equipment selection, refrigerant piping, drainage, electrical supply and controls as one project.

SCA / TECHNICAL LIBRARY

Mitsubishi Heavy
VRF catalogue

Open the technical tables and equipment information in the SCA catalogue. Each model page links directly to its catalogue section.