Condition rooms without relying on a suspended ceiling. We choose the location around the occupied space, the return-air path and a reliable condensate route.

Technical reference
- Family: WTHXEV…HHY — Wall-mounted VRF indoor units
- Nominal cooling range: 1.7–8.4 kW — According to the selected model
- Fan control: 6 fan levels — DC motor; indoor fan power is not total VRF-system input
- Example casing: 270 × 845 × 203 mm — Applies to the 15 / 22 / 28 / 36 code subset
Keep the air jet clear of daily use
We assess desks, beds, seating and window loads before choosing the wall position. A short refrigerant route can be convenient, but not at the cost of air blowing continuously onto occupants or becoming trapped behind furniture. Curtains and later furniture changes also matter to the final discharge direction.
Separate fan watts from system consumption
The indoor unit’s DC fan has its own electrical input. That figure does not describe the compressor’s demand or the consumption of the complete VRF system. We compare system performance at actual operating conditions, using indoor and outdoor equipment and their simultaneous loads together.
Self-cleaning supports regular care
A self-cleaning function does not remove the need to maintain filters and check condensate drainage. We provide access for the cover, filter and service connections. Condensate gradients or a selected pump arrangement are coordinated with the wall finish, so the installation remains both tidy and serviceable.
Choose capacity and control for the room
The family contains different capacities and casing sizes. The 270 × 845 × 203 mm example belongs only to the stated code subset. We check the room’s heat gains, operating hours, selected fan duty and compatible controller. The outdoor-air requirement is handled separately from the indoor unit’s room-air circulation.
Our selection checklist
- Check air direction against furniture and occupancy
- Verify the selected model’s actual dimensions and capacity
- Coordinate controls, filter access and condensate drainage
Frequently asked questions
Does low indoor fan power mean low total system consumption?
No. Indoor fan input is one part of the system. Outdoor-unit demand and actual operating conditions must also be considered.
Does self-cleaning replace filter maintenance?
No. Filters, drainage and the installation still require routine inspection and maintenance.
Explore the complete system
FujiTherma VRF systems- FujiTherma A Series
- FujiTherma X3 Series
- FujiTherma Cassette Indoor Units
- FujiTherma Concealed Ducted Indoor Units
- FujiTherma Console Indoor Units
Plan your system with SCA
Share your floor plan, operating hours and preferred installation locations. Our Istanbul-based team supports projects across the Marmara region, from site survey and equipment selection to installation, testing and commissioning.
We coordinate the refrigerant circuit, electrical supply, drainage, ventilation and controls as one project. Your proposal identifies the selected models, accessories and installation scope.
Discuss your project Call SCA