SCA Mühendislik

SCA / MECHANICAL ENGINEERING

Mitsubishi Heavy Wall-mounted Indoor Units.

Wall-mounted units can solve room conditioning where a suspended ceiling is unavailable. We plan the discharge direction, service access, pipe route and condensate drainage around the occupied space.

Istanbul based · Serving the Marmara region

Mitsubishi Heavy Wall-mounted Indoor Units

Wall-mounted units can solve room conditioning where a suspended ceiling is unavailable. We plan the discharge direction, service access, pipe route and condensate drainage around the occupied space.

Mitsubishi Heavy Wall-mounted Indoor Units

Technical reference

  • Family: FDK15–90 KXZE1 — Nominal cooling range 1.5–9.0 kW
  • Example capacity: 1.5 / 1.7 kW — FDK15KXZE1 cooling / heating at ISO-T1 conditions
  • Example casing: 290 × 870 × 230 mm — Height × width × depth for FDK15KXZE1
  • Outdoor-air connection: None for the example unit — Room circulation does not replace required ventilation

Choose the wall around airflow

A convenient pipe entry is not always the best discharge position. We assess beds, desks, seating and the window load before agreeing a location. The air jet needs a clear path and should avoid persistent direct exposure to occupants. Curtains, wardrobes and future partitions can change that path.

Keep capacity and room use aligned

Oversizing can make control harder during low-load hours, while insufficient capacity shows up at the busiest or hottest time. We calculate the room’s sensible and latent loads and check the unit at the relevant design conditions. The smallest published capacity is useful only when it matches the actual room.

Drainage is part of the finished wall

Condensate must leave through an appropriate gradient or a selected pump arrangement. We coordinate the drain, insulated refrigerant pipes and wall penetration before finishing surfaces. Access for cleaning and inspection matters as much as concealing the services.

Confirm controller functions before ordering

Flap control is dependent on the controller. The catalogue notes that RCH-E3 does not provide flap-control functionality. We identify the compatible controller and required operating permissions in the proposal, so the installed control behaviour matches the intended room use.

Our selection checklist

  • Check discharge direction against furniture
  • Calculate design load and selected fan duty
  • Provide a reliable condensate route
  • Confirm controller and flap-control compatibility

Frequently asked questions

Does this unit bring fresh air into the room?

The example FDK unit has no outdoor-air connection. We assess the room’s ventilation requirement separately.

Are all controller functions interchangeable?

No. Controller compatibility and available functions must be checked against the exact indoor unit and selected control model.

Explore the complete system

Mitsubishi Heavy Industries VRF systemsRead the SCA Mitsubishi Heavy catalogue

Plan your system with SCA

Share your floor plan, operating hours and preferred installation locations. Our Istanbul-based team supports projects across the Marmara region, from site survey and equipment selection to installation, testing and commissioning.

We coordinate the refrigerant circuit, electrical supply, drainage, ventilation and controls as one project. Your proposal identifies the selected models, accessories and installation scope.

Discuss your project Call SCA

FROM SURVEY TO INSTALLATION

Let’s put the right
system in place.

Share your plans, operating priorities and existing equipment.
We’ll define the scope together.